Sustainability
Every kilo of cement taken out of the mix is CO₂ that is not emitted.
Lower footprint,
same concrete
Concrete's carbon footprint lies almost entirely in the cement — around 90% — and, within the cement, in the clinker. Taking cement out of the mix is the most direct way to lower it, as long as performance is maintained.
According to the GCCA roadmap, clinker production accounts for 88% of the emissions in the cement–concrete chain (source); mixing and transporting the concrete account for ~5% (source).
17kg CO₂/m³
Compared with an HA-30 control mix with 300 kg/m³ of the same cement (CEM II/A-M 42.5 R).
~9%
Footprint reduction per cubic metre of concrete.
[DATA: cumulative t CO₂e avoided]
Cumulative total in projects already completed with CarbonLith.
How the CO₂ saving is calculated
The EPD only declares the footprint of 1 kg of CarbonLith. The saving in concrete has to be calculated like this:
Net saving = C · 0.10 · EFcement − D · 0.714
- C
- kg of cement/m³ in the control mix
- EF
- kg CO₂e per kg of the cement used
- D
- CarbonLith dose (kg/m³)
- 0.714
- GWP-total of CarbonLith according to the EPD
The penalty from the product itself is minimal: 0.14–0.16 kg CO₂e/m³.
With the cement from the EPD itself (CEM II/A-M (P-L) 42.5 R), the implied factor is ~0.56 kg CO₂e/kg. Result by control mix:
| Cement in the control mix (kg/m³) | Cement saved (kg/m³) | Net saving (kg CO₂e/m³) |
|---|---|---|
| 300 | 30 | 16.7 |
| 350 | 35 | 19.5 |
| 430 | 43 | 24.0 |
The 17 kg CO₂e/m³ on this page (16.7 rounded) correspond to an HA-30 control mix with 300 kg/m³ of CEM II/A-M (P-L) 42.5 R: all the factors come from the verified EPD.
The EPD covers 1 kg of product (A1–A3); each customer calculates the reduction with their own mix.
The calculation does not include the saving on admixtures dosed in proportion to the cement: when cement is taken out, their consumption falls too.
EPD data
CarbonLith has an Environmental Product Declaration (EPD) verified by a third party, so you can include its data in the footprint calculation for your concrete and your project.
View the EPDRegistered as CarbonLith Structural, EPD-IES-0031628:002
- Registration no.
- EPD-IES-0031628:002
- Programme / verification
- International EPD System; independent third-party verification (ISO 14025)
- Standards
- ISO 14025:2006, EN 15804:2012+A2:2019/AC:2021, PCR 2019:14 v2.0.1
- Scope
- Cradle to gate, modules A1–A3
- Declared unit
- 1 kg of product
- GWP-total
- 0.714 kg CO₂e/kg
- Declared dose
- 0.2 kg/m³ of concrete (0.01% of dry mass)
- Issue date / validity
- 13-07-2026 / until 12-07-2031
- LCA carried out by
- Applus+ LGAI Technological Center
- Other certifications
- UNE-EN 934-2 (T2), Spanish Structural Code (RD 470/2021), ISO 9001
Shall we talk?